# Bearing Grease Temperature Limits: NLGI, Dropping Point and Range

Choosing the right grease is not only about base oil viscosity. Temperature decides whether the grease stays soft, hardens, bleeds oil or melts. Pushing a grease past its temperature limit is one of the most common reasons bearings fail before their calculated life.

## Continuous Operating Temperature

Each grease has a recommended continuous temperature range. General lithium greases work from about -20°C to +120°C. High-temperature greases (polyurea, complex soap, silicone) extend the upper end to 150–180°C. Above the limit, the base oil oxidizes, the thickener breaks down and the grease hardens or liquefies.

## Dropping Point

The dropping point is the temperature at which the grease turns from semi-solid to liquid and drips. It is a reference point, not the operating limit. A lithium grease may have a dropping point around 180°C but should not run continuously above 120°C. Use the manufacturer's operating range, not the dropping point, for selection.

## Life Halving Rule

Grease life roughly halves for every 15°C rise in operating temperature above 70°C. A bearing running at 100°C needs relubrication four times as often as one at 70°C. This is why hot running shortens both grease and bearing life. See [relubrication interval](/bearing-lubrication-maintenance/58148.html).

## Low Temperature Limits

At low temperature, grease stiffens and the bearing drags. Standard lithium greases get thick below -20°C. For outdoor or freezer duty, use synthetic base oil greases (PAO, ester) that stay fluid to -40°C or lower. NLGI grade also matters: NLGI 0 or 1 flows more easily at start-up.

## Mixing Greases

Do not mix greases with different thickener types (lithium, calcium, polyurea, aluminum complex). Incompatible greases can soften, liquefy or lose structure. When changing grease brand, flush the housing and repack. See [lubrication mistakes](/bearing-lubrication-maintenance/58161.html).

## FAQ

**Q: What grease for 150°C continuous?**  
A: Use polyurea or synthetic high-temperature grease, and shorten the relubrication interval accordingly.

**Q: Is a higher dropping point always better?**  
A: Not for selection. The continuous operating range matters more than dropping point.