What is a 16000 series bearing size? A 16000 series bearing is a metric deep groove ball bearing with a 10 mm bore diameter, and the full 16000 designation encodes the bore, outer diameter, and width. Per ISO 15:2017 metric rolling bearing designation system, the leading digit before the dimension series indicator marks the bore size. In the 16000 series, the bore is fixed at 10 mm, while the outer diameter and width come in standardized combinations. Per MS Bearings factory data 2024, the common sizes run 16000 (10 x 26 x 8 mm), 16001 (12 x 28 x 8 mm), 16002 (15 x 32 x 9 mm), 16003 (17 x 35 x 10 mm), and 16004 (20 x 42 x 12 mm), with dynamic load ratings from about 5 kN to 13 kN and grease-lubricated speed ratings from 8,000 to 12,000 rpm.
These small deep groove ball bearings appear across electric motors, gearboxes, pumps, conveyors, agricultural machinery, household appliances, and automotive auxiliary systems. In most replacement situations, the 16000 series size you need is identified by stamping or engraving on the old bearing shield, which carries the exact base number. This guide covers the dimension logic, typical load and speed data, application notes, and sourcing criteria.
16000 Series Bearing Size: How the Designation Works
How is a 16000 series bearing size decoded? The prefix 16 identifies the bore, and the remaining three digits designate the outer diameter and width combination, so 16000 always means a 10 mm bore and does not vary.
- Bore (mm): fixed by the 16 prefix at 10 mm
- Outer diameter (mm): varies with the suffix (16000 = 26, 16001 = 28, 16002 = 32, 16003 = 35, 16004 = 42)
- Width (mm): standardized alongside the outer diameter (8, 8, 9, 10, 12)
- Boundary dimensions: per ISO 15:2017 and DIN 625
Clear the shield of grease or oil and read the stamped marking. Many failures trace back to a mis-read replacement bearing: an installer who buys a 6000 series in place of a 16000 series because both look small will still secure a 10 mm bore in some sizes, but width and outer diameter differ, causing house fits, seal lip contact, or abnormal clearance.
Cross-reference the base number against the actual shaft and housing dimensions on the drawing. Do not size a replacement by visual similarity alone, especially on motor shafts with tight shoulder-to-seal-face distances.
16000 Series Bearing Size Chart and Standard Dimensions
Which 16000 series bearing dimensions are standard? The five most widely stocked 16000 sizes keep a 10 to 20 mm bore and a compact cross-section, and dynamic load ratings rise with the section, as shown in the table.
| Bearing number | Bore d (mm) | OD D (mm) | Width B (mm) | Dynamic load C (kN) | Static load C0 (kN) | Grease speed rating (rpm) | Open / shield / sealed |
|---|---|---|---|---|---|---|---|
| 16000 | 10 | 26 | 8 | 5.0 | 2.2 | 12000 | all |
| 16001 | 12 | 28 | 8 | 5.8 | 2.5 | 11500 | all |
| 16002 | 15 | 32 | 9 | 7.5 | 3.4 | 11000 | all |
| 16003 | 17 | 35 | 10 | 9.6 | 4.2 | 9500 | all |
| 16004 | 20 | 42 | 12 | 13.0 | 5.7 | 8000 | all |
The data above comes from MS Bearings factory data 2024 for standard grades and reflects grease-lubricated, shielded bearings.
For maintenance, identify the failure cause and address it before installing a new 16000 series bearing. Overheating, low clearance after press-fit, and debris ingress are the most common causes of small bearing failure in electric motors, pumps, and conveyors. Use a caliper to verify the old OD and width if the marking is worn, and measure the housing bore and shaft shoulder dimensions against the new bearing fit per ISO 279:2022 (typical k5 shaft, H7 housing for these sizes).
When should lubrication be changed on a 16000 series bearing? Lubricate at installation with a reputable industrial grease, then inspect every 2,500 to 5,000 hours and re-grease with NLGI 2 grease in the 20 to 120 °C range for standard applications.
16000 Series Bearing Size for Electric Motors and Pumps
Can a 16000 series bearing size work in electric motors and pumps? A 16000 series bearing in the correct size delivers predictable load capacity and speed in small motors, pumps, and fans, and its choices are mostly about sealing and clearance rather than bearing type.
- Typical uses: small electric motors, geared motors, pumps, fans, and conveyor heads
- Common seals: open (N), metal shield (ZZ or Z), or contact rubber seal (RS or 2RS)
- Typical clearance: C3 for motor and pump shafts with tight fits
- Dynamic load range: about 5.0 to 13.0 kN
- Noise: quiet when matched to housing geometry and not preloaded by an oversized fit
Run-out is a useful check when noise or vibration appears. For a 16000 series with a 10 mm bore, measure radial run-out of about 0.025 mm or less; larger run-out indicates housing bore distortion or a worn shaft shoulder.
Where to buy 16000 series bearing size parts for OEM and maintenance? Replacement and OEM-grade 16000 series bearings are available from factory suppliers, bearing distributors, and qualified MRO vendors. For OEM replacements, specify the exact number (such as 16002-2RS) and request material, tolerance, and certification details. Per MS Bearings factory data 2024, lead time is about 24 hours for stocked sizes, MOQ is 50 pieces, certification is ISO 9001:2015, and warranty is 12 months.
FAQ