This guide walks through a complete bearing life calculation from first principles. If you have ever wondered how engineers pick the right bearing size, this is the process.

Start with load rating basics and equivalent load factors.

The Application

A 3 kW electric motor runs at 1500 rpm, 24 hours a day. The drive-end bearing sees Fr = 1.2 kN radial load and negligible axial load. Required life: 40,000 hours. We need to pick a standard deep groove ball bearing.

Step 1: Calculate Required Dynamic Load Rating

The L10 life formula in hours is:

L10h = (10^6 / (60 * n)) * (C / P)^3

We need L10h = 40,000, n = 1500 rpm, P = 1.2 kN (no axial load, so P = Fr).

Rearrange to solve for required C:

C = P * (L10h * 60 * n / 10^6)^(1/3)
C = 1.2 * (40000 * 60 * 1500 / 1000000)^(1/3)
C = 1.2 * (3600)^(1/3)
C = 1.2 * 15.33
C = 18.4 kN

Step 2: Pick a Bearing with C Above Required

Looking at the 62-series:

  • 6204: C = 12.8 kN - too small
  • 6205: C = 14.0 kN - still too small
  • 6206: C = 19.5 kN - above 18.4 kN, selected

A 6206 deep groove ball bearing meets the 40,000-hour target.

Step 3: Verify Speed and Clearance

The 6206 has a grease speed limit of around 11,000 rpm. Our 1500 rpm is well below. Use C3 clearance for a motor because the inner ring runs hotter than the outer ring.

Step 4: Check Static Safety

The static load rating C0 for 6206 is 11.2 kN. The equivalent static load P0 = Fr = 1.2 kN. The safety factor C0/P0 = 9.3, well above the minimum 1.0. No brinelling risk.

Result

The selected bearing is 6206-2RS/C3: double-sealed, C3 internal clearance, pre-greased. It meets the 40,000-hour life target with margin.

Frequently Asked Questions

Why use L10 instead of L50?

L10 is the 90 percent survival life - the bearing will last this long 9 out of 10 times. It is the standard engineering design target. L50 is average life, used for reference only.

What if the calculated C is between two bearing sizes?

Always go up to the next size. The extra cost is small compared to the downtime of a premature failure.

Does this calculation include lubrication?

No. The basic L10 assumes ideal lubrication. In practice, a lubrication factor of 0.6 to 0.8 is applied for dirty or poorly lubricated applications.

Related Reading