When grease is not enough - high speed, high temperature, heavy load - oil lubrication systems take over. This guide compares the four common oil lubrication methods and when each is appropriate.
Start with grease vs oil.
Splash Lubrication (Oil Bath)
The bearing dips into an oil sump, and oil is flung onto the rolling elements as it rotates. Simple, no pump, no filter. Used in gearboxes, low-speed reducers and small pumps.
Keep the oil level at the center of the lowest rolling element. Too high and the bearing churns oil and overheats; too low and it runs dry. Maximum speed is limited to about half the grease limit.
Circulation Lubrication
A pump draws oil from a tank, filters it, and feeds it to the bearing. The oil drains back to the tank, often through an oil cooler. This system both lubricates and cools the bearing.
Common in large gearboxes, centrifugal compressors and continuous process machinery. The oil can be continuously monitored for contamination, water content and metal particles.
Oil-Air (Mist) Lubrication
A small metered amount of oil is carried to the bearing by a continuous stream of compressed air. Only a tiny oil film reaches the contact, reducing churning heat. This is the standard for high-speed machine tool spindles running at 10,000 rpm or more.
Oil-air systems use much less oil than circulation systems and generate almost no churning loss.
Jet Lubrication
A high-pressure oil jet shoots directly into the contact zone between the rolling elements and raceway. This is used for extremely high-speed applications such as gas turbine bearings and large compressor shaft ends, where oil-air cannot deliver enough oil or cooling.
Which System to Choose
| Speed Range | Recommended System |
|---|---|
| Below 50% of grease limit | Grease or oil bath |
| 50-100% of grease limit | Oil bath or circulation |
| 100-200% of grease limit | Circulation or oil-air |
| Above 200% of grease limit | Oil-air or jet |
Frequently Asked Questions
Can I use circulation oil to also cool the bearing?
Yes. Circulation oil carries heat out to an external cooler. This is the main reason large gearboxes and compressors use oil instead of grease.
Why is oil-air used for machine tool spindles?
Spindles run at very high speed with light load. Excess oil causes churning heat and ruins accuracy. Oil-air delivers just enough oil to form a film without heat.
How often do I change circulating oil?
Typically every 6 months to 1 year, depending on oil condition monitoring. Test for water content, acid number and particle count before deciding.
Related Reading
Need Oil Lubrication Design?
MS Bearing supplies bearings for oil bath, circulation and oil-air lubrication. Send us your speed and temperature, and our engineers will recommend the lubrication system and oil grade.